Style | Model | Coefficient of Volume | Orifice Dia. | Pipe Size | Seal Material | Voltage | Watts | Price | |
---|---|---|---|---|---|---|---|---|---|
A | 6200-B60-AAC6B | 0.52 | 5/32" | 3/8" | Buna N | 24 VAC | 8 | £61.64 | |
A | 6200-B60-AAB6B | 0.52 | 5/32" | 1/4" | Buna N | 24 VAC | 8 | £61.64 | |
A | 6200-E60-AAC7B | 0.52 | 5/32" | 3/8" | EPDM | 120 VAC | 8 | £63.23 | |
A | 6200-B60-AAC3B | 0.52 | 5/32" | 3/8" | Buna N | 24 VDC | 10 | £61.64 | |
A | 6200-E60-AAB3B | 0.52 | 5/32" | 1/4" | EPDM | 24 VDC | 10 | £65.40 | |
A | 6200-E60-AAB2B | 0.52 | 5/32" | 1/4" | EPDM | 12 VDC | 10 | £63.23 | |
A | 6200-E60-AAB7B | 0.52 | 5/32" | 1/4" | EPDM | 120 VAC | 8 | £63.23 | |
A | 6200-E60-AAB6B | 0.52 | 5/32" | 1/4" | EPDM | 24 VAC | 8 | £63.23 | |
A | 6200-B60-AAC7B | 0.52 | 5/32" | 3/8" | Buna N | 120 VAC | 8 | £61.64 | |
A | 6200-B60-AAB2B | 0.52 | 5/32" | 1/4" | Buna N | 12 VDC | 10 | £61.64 | |
A | 6200-B60-AAB7B | 0.52 | 5/32" | 1/4" | Buna N | 120 VAC | 8 | £61.64 | |
A | 6200-B60-AAB3B | 0.52 | 5/32" | 1/4" | Buna N | 24 VDC | 10 | £61.64 | |
A | 6200-B60-AAC2B | 0.52 | 5/32" | 3/8" | Buna N | 12 VDC | 10 | £61.64 | |
A | 6200-E60-AAC6B | 0.52 | 5/32" | 3/8" | EPDM | 24 VAC | 8 | £63.23 | |
A | 6200-E60-AAC3B | 0.52 | 5/32" | 3/8" | EPDM | 24 VDC | 10 | £63.23 | |
A | 6200-E60-AAC2B | 0.52 | 5/32" | 3/8" | EPDM | 12 VDC | 10 | £63.23 | |
A | 6200-E70-AAC2B | 0.61 | 13/64" | 3/8" | EPDM | 12 VDC | 10 | £63.23 | |
A | 6200-B70-AAB3B | 0.61 | 13/64" | 1/4" | Buna N | 24 VDC | 10 | £61.64 | |
A | 6200-E70-AAB3B | 0.61 | 13/64" | 1/4" | EPDM | 24 VDC | 10 | £63.23 | |
A | 6200-E70-AAB2B | 0.61 | 13/64" | 1/4" | EPDM | 12 VDC | 10 | £63.23 | |
A | 6200-E70-AAB7B | 0.61 | 13/64" | 1/4" | EPDM | 120 VAC | 8 | £63.23 | |
A | 6200-E70-AAB6B | 0.61 | 13/64" | 1/4" | EPDM | 24 VAC | 8 | £63.23 | |
A | 6200-B70-AAB7B | 0.61 | 13/64" | 1/4" | Buna N | 120 VAC | 8 | £61.64 | |
A | 6200-B70-AAB2B | 0.61 | 13/64" | 1/4" | Buna N | 12 VDC | 10 | £63.74 | |
A | 6200-E70-AAC7B | 0.61 | 13/64" | 3/8" | EPDM | 120 VAC | 8 | £63.23 | |
A | 6200-B70-AAB6B | 0.61 | 13/64" | 1/4" | Buna N | 24 VAC | 8 | £61.64 | |
A | 6200-B70-AAC6B | 0.61 | 13/64" | 3/8" | Buna N | 24 VAC | 8 | £61.64 | |
A | 6200-B70-AAC7B | 0.61 | 13/64" | 3/8" | Buna N | 120 VAC | 8 | £61.64 | |
A | 6200-B70-AAC2B | 0.61 | 13/64" | 3/8" | Buna N | 12 VDC | 10 | £61.64 | |
A | 6200-B70-AAC3B | 0.61 | 13/64" | 3/8" | Buna N | 24 VDC | 10 | £61.64 | |
A | 6200-E70-AAC6B | 0.61 | 13/64" | 3/8" | EPDM | 24 VAC | 8 | £62.50 | |
A | 6200-E70-AAC3B | 0.61 | 13/64" | 3/8" | EPDM | 24 VDC | 10 | £63.23 |
Major factors include the required flow rate and pressure, the type of fluid or gas being controlled, temperature, humidity, voltage and power consumption.
They have a response time of 16 to 40 milliseconds (complete cycle).