Sign In

EATON E2J Type Mining Complete Molded Case Circuit Breakers

Eaton E2J type mining complete moulded case circuit breakers offer superior protection against electrical damage to connected devices in harsh mining or industrial environments. They prevent ...Read More

Filter
StyleModelCircuit Breaker TypeNumber Of PolesVoltagePrice
A
E2J3150
E2J3600V AC/250V DC£5,573.31
A
E2J3225AWA06U18
E2J3600V AC/250V DC£7,744.47
B
E2J3100
E2J3600V AC/250V DC£5,410.97
A
E2J3250MJW
E2J3600V AC/250V DC£5,081.71
A
E2J3175WA06U18
E2J3600V AC/250V DC£7,728.88
A
E2J3250
E2J3600V AC/250V DC-
RFQ
A
E2J3150WM01
E2J3600V AC/250V DC£5,559.63
A
E2J3225AWU17
E2J3600V AC/250V DC-
RFQ
A
E2J3175WM01
E2J3600V AC/250V DC£5,093.43
A
E2J3225DWS10
E2J3600V AC/250V DC£6,813.98
A
E2J3250MDW
E2J3600V AC/250V DC£5,081.71
A
E2J3250MDWU18
E2J3600V AC/250V DC£7,406.44
A
E2J3250WU18
E2J3600V AC/250V DC£7,147.74
A
E2J3125WU17
E2J3600V AC/250V DC£7,048.07
A
E2J3225AW
E2J3600V AC/250V DC£5,081.71
A
E2J3200W
E2J3600V AC/250V DC£5,081.71
A
E2J3225WU17
E2J3600V AC/250V DC£7,032.46
A
E2J3150W
E2J3600V AC/250V DC-
RFQ
A
E2J3175WU18
E2J3600V AC/250V DC£7,032.46
A
E2J3225DWU17
E2J3600V AC/250V DC£7,048.07
A
E2J3250MKWU18
E2J3600V AC/250V DC£7,048.07
A
E2J3225W
E2J3600V AC/250V DC£5,081.71
A
E2J3200WU18
E2J3600V AC/250V DC£7,032.46
A
E2J3225AWU50
E2J3600V AC/250V DC-
RFQ
A
E2J3250MW
E2J3600V AC/250V DC£5,081.71
A
E2J3200WA06U18
E2J3600V AC/250V DC-
RFQ
A
E2J3225WU18
E2J3600V AC/250V DC£7,032.46
A
E2J3225DWA06U18
E2J3600V AC/250V DC£7,744.47
A
E2J3250WU17
E2J3600V AC/250V DC£7,032.46
A
E2J3150WS10
E2J3600V AC/250V DC£7,032.46
A
E2J3225DWU18
E2J3600V AC/250V DC£7,048.07
A
E2J3250MGWT29
E2J3600V AC/250V DC£7,032.46
A
E2J3100W
E2J3600V AC/250V DC£5,081.71
A
E2J3200WA06
E2J3600V AC/250V DC£6,008.31
A
E2J3250MAWD01
E2J3600V AC/250V DC£5,136.31
A
E2J3150WU18
E2J3600V AC/250V DC£7,512.33
A
E2J3225WS10
E2J3600V AC/250V DC£7,048.07
A
E2J3200
E2J3600V AC/250V DC£5,573.31
A
E2J3250MAW
E2J3600V AC/250V DC£5,081.71

Working Mechanism

  • These 3-pole circuit breakers automatically interrupt the flow of electricity to the circuit, protecting the equipment on detecting a fault.
  • They can be reset by switching the handle to off & then on position, once the fault has been resolved.
  • Electronic trip units in these breakers can be used for monitoring & protection of the units.

Features

  • Eaton E2J type mining complete moulded case circuit breakers have a J-frame to house the trip unit & all current-carrying devices inside their frame.
  • These circuit breakers have a built-in test kit for electronic field testing and a push-to-trip button to check the tripping function during scheduled maintenance.
  • They offer a current rating ranging from 100 to 250A & a voltage rating of 600V and also have a sliding handle with ON & OFF positions for easy identification of the breaker's status.

Compatible Accessories

  • Shunt Trips: These devices mechanically trip the breakers remotely by applying power (from an external source) to their shunt trip terminals.
  • Auxiliary Switches: They connect to these circuit breakers to remotely indicate whether their contacts are open or closed.
  • Alarms: They indicate the tripping of the selected breaker during remote operation.

Standards and Approvals

  • UL
  • IEC
  • CSA

Frequently Asked Questions

What are the interrupt ratings of these Eaton E2J type mining complete moulded case circuit breakers?

  • 65kAIC at 240VAC
  • 35kAIC at 480VAC
  • 18kAIC at 600VAC
  • 10kAIC at 250VDC

What is the difference between a thermal-magnetic and a magnetic-only circuit breaker?

The thermal-magnetic breaker has both thermal and magnetic elements for overload trip & inrush / instantaneous trip, respectively. The magnetic-only breakers do not have thermal protection and are mainly used for motor protection.

What are the points to inspect before operating these Eaton E2J type mining complete moulded case circuit breakers?

  • Remove the dust, dirt, grease, moisture or foreign contaminants from the unit.
  • Check that the unit's switch is free to move by switching the unit ON & OFF several times.
  • Inspect the unit for any cracks, chipping or discolouration. Tighten the terminals & connectors. Check the mounting hardware.
  • Remove any safety hazards near the installed area.