Change Country
- Sign in
- Submit RFQ
Get it by May 3, Friday
£9.99 Flat Shipping £9.99 flat shipping is applicable on orders with an aggregate weight less than 10kg. Orders exceeding 10kg will be charged default shipping rates
Payment Methods
Delivery Partners
Step 1 Add the items into your cart or submit a Purchase order
Step 2 Checkout, select NET30 payment (provide company registration and VAT number)
Step 3 Delivery via TNT or Royal Mail and receive invoice for payment in 30-days
Step 4 Make payment via BACS to our factoring partner,
Item | Circuit Breaker |
AC Voltage Rating | 600 VAC |
Actuator | Toggle |
Amps | 15 |
Circuit Breaker Type | Standard |
Current Rating | 15A |
DC Voltage Rating | 250 VDC |
Depth | 3.39" |
Frame Size | 60A/HD |
Frequency | 50/60 Hz |
Height | 6.42" |
High Amp Trip Setting | 750A |
Low Amp Trip Setting | 350A |
Magnetic Hold Current | 350A |
Magnetic Tripping Current | 750A |
Max. AIR Rating | Not Rated |
Max. Breaking Capacity | 25kA @ 240V AC |
Max. Wire Size | 3/0 AWG |
Min. Wire Size | 14 AWG |
Mounting | Free Standing |
Mounting Style | Free Standing |
Number of Poles | 2 |
Phase | 1 |
Terminal Connection | Line/Load Lug |
Trip Type | Thermal Magnetic |
UPC | 785901458869 |
Voltage Rating | 600V AC, 250V DC |
Width | 4.09" |
Wire Size | 3 AWG(Cu), 14 AWG(Al) |
Ship weight (kg) | 2.71 |
Ship height (cm) | 23.88 |
Ship length (cm) | 18.69 |
Ship width (cm) | 14.58 |
HS code | 8536200020 |
A. Fixed MCCB trip settings have predetermined overload & short-circuit protection values that cannot be changed by the user. Adjustable MCCBs allow users to customise trip settings within certain limits, providing more flexibility to match specific application requirements.
A. Square D offers MCCBs in single-pole, double-pole, three-pole and four-pole options. The pole configuration refers to the number of conductors the MCCB can interrupt simultaneously.
A. Regular testing and maintenance are recommended to ensure the proper functioning of MCCBs.
A. Inverse time trip settings in MCCBs provide a delayed response to overcurrents. The longer the overcurrent persists, the quicker the trip occurs. Instantaneous trip settings, on the other hand, result in an immediate trip response once the current exceeds a certain threshold.
Product | Model | Magnetic Tripping Current | Amps | Current Rating | Max. Breaking Capacity | Number of Poles | Phase | Voltage Rating | Width | Price | |
---|---|---|---|---|---|---|---|---|---|---|---|
HDL36100 | 1700A | 100 | 100A | 25kA @ 240V AC | 3 | 3 | 600V AC, 250V DC | 4.09" | £2,128.32 | ||
HGL36040 | 850A | 40 | 40A | 65kA @ 240V AC | 3 | 3 | 600V AC, 250V/500V DC | 4.1" | £2,267.22 | ||
HGL36100 | 1700A | 100 | 100A | 65kA @ 240V AC | 3 | 3 | 600V AC, 250V/500V DC | 4.1" | £2,730.49 | ||
HJA36100 | 1700A | 100A | 100A | 100kA @ 240V AC | 3 | - | 600V AC, 250V/500V DC | - | £1,643.26 | ||
HJL36040 | 850A | 40A | 40A | 100kA @ 240V AC | 3 | - | 600V AC, 250V/500V DC | - | £963.38 |
Contact your account manager right away to get personal advice.
We're available Monday through Friday, from 07:30 until 17:00.