Sign In
Flat Shipping

Flat Shipping at £9.99 + VAT

DWYER INSTRUMENTS 1910-00 Pressure Switch, SPDT | AH2CWK 25E960

DWYER INSTRUMENTS 1910-00 Pressure Switch, SPDT

Item: AH2CWK Model: 1910-00Cross Ref: 25E960
In Stock

Get it by May 6, Monday

£9.99 Flat Shipping £9.99 flat shipping is applicable on orders with an aggregate weight less than 10kg. Orders exceeding 10kg will be charged default shipping rates

£148.20 /unit (Inc. VAT)
Trade Prices Available
ADD TO CART
REQUEST A QUOTE

Payment Methods

Delivery Partners

How NET30 Works

Step 1 Add the items into your cart or submit a Purchase order

Step 2 Checkout, select NET30 payment (provide company registration and VAT number)

Step 3 Delivery via TNT or Royal Mail and receive invoice for payment in 30-days

Step 4 Make payment via BACS to our factoring partner,

Product Specifications:

ItemPressure Switch
Approx Deadband Max. Set Point0.04
Approx Deadband Min. Set Point0.04
Connection Size1/8"
Connection TypeFNPT
Current Rating15 A @ 120 to 480V AC
Deadband0.4 min.
Frequency60 Hz
HP1/8 hp @ 125V AC, 1/4 hp @ 250V AC
Mounting OrientationDiaphragm in Vertical position
Operating Range0.07 to 0.15" wc
Temp. Range-30 Deg. to 130 Deg. F

Shipping Info:

Ship weight (kg) 0.45
Ship height (cm)2.54
Ship length (cm)2.54
Ship width (cm)2.54
Country of OriginUS

Product Details:

Dwyer air pressure switch, 1910-00 is designed for clogged filter detection, air conditioning, defrost cycle initiation and variable air volume controller operations.

Working Mechanism:

  • A differential pressure switch consists of two pressure ports, one on each side of the switch.
  • It measures the difference in pressure between these ports using the diaphragm.
  • When the pressure difference exceeds or falls below the set points, the switch's contacts are activated, either opening or closing an electrical circuit.

Features:

  • Dwyer 1910-00 low differential pressure switch features lightweight & compact construction for an accurate fit and long-term operation.
  • This unit has an SPDT (single-pole double-throw) switch for on / off function and to detect any change in the vacuum level.
  • It has common, normally open & normally closed electrical connections and comes with 1/8 inch female NPT connections for a perfect seal.
  • It can operate at temperatures ranging from -30 to 180 degrees Fahrenheit.

Compatible Accessories:

  • Dwyer A-489 Static Pressure Tip: It comes with a mounting flange and is designed for monitoring static pressure drop across cooling coils, air filters, discharge pressures & blower inputs.
  • Dwyer A-399 Duct Pressure Monitor Kit: It is used with standard or manual reset model switches comprising tubing, mounting flange and adapters.
  • Dwyer A-329 Street Ell: It is a brass adapter used for applications requiring right-angle connections.
  • Dwyer A-302F-A Stainless Steel Static Pressure Tip: It comes with a mounting flange, including 3/16 inch ID plastic or rubber tubing, 4-inch insertion depth and mounting screws.

Standards and Approvals:

  • FM
  • UL
  • CE
  • CSA

Frequently Asked Questions:

Q. What is the difference between a static pressure sensor and a differential pressure sensor?

A. A differential pressure sensor, often known as a DP sensor, is a unique kind of pressure sensor that gauges the difference in pressure between two ports on a device. It is distinct from a static or absolute pressure sensor that uses a single port to measure pressure.

Q. What should be the position of the pressure controller while installation?

A. It is calibrated to be used in a vertical mounting position.

Q. How do you adjust a differential pressure switch?

A. Only the cut-off pressure will change when the differential is altered. Cut-off pressure can be increased or decreased by turning the differential nut in either clockwise or counterclockwise direction.

Q. What are the maintenance requirements for a differential pressure switch?

A. To maintain optimal performance, regularly inspect the switch for any signs of damage, contamination or blockages. Clean or replace any clogged or dirty components. Additionally, verify the switch's calibration periodically to ensure accurate operation.

Q. Should I install this Dwyer Instruments 1910-00 compact low differential pressure switch vertically or horizontally?

A. It should be mounted in such a way that the diaphragm stays in the vertical position.

Product Variants

ProductModelApprox Deadband Max. Set PointApprox Deadband Min. Set PointCurrent RatingPrice
DWYER INSTRUMENTS 1626-5 Pressure Switch, Single Pole Double Throw Type | AH2CWM 25E992
1626-50.350.1515 A @ 120 to 480V AC£690.07
DWYER INSTRUMENTS 1950-0-2F Pressure Switch, Explosion Proof, 1/8 Inch Female NPT Connection | AH2CXE 25F035
1950-0-2F0.150.1015 A @ 125, 250, 480V AC£439.55
DWYER INSTRUMENTS DA-7031-153-6 Pressure Switch, Range 5-100 psig Range | AH2CXL 25F268
DA-7031-153-6---£928.15

Explore Products

Contact us

Contact your account manager right away to get personal advice.
We're available Monday through Friday, from 07:30 until 17:00.

DWYER INSTRUMENTS 1910-00 Pressure Switch, SPDT
£148.20 /unit (Inc. VAT)