Sign In

GENERAL ELECTRIC TED Series Circuit Breakers

General Electric TED Series circuit breakers safeguard electrical equipment, machinery and power distribution systems from overloads & short circuits.

Filter
AC Voltage Rating: 480 VAC , AIR @ 240VAC: 18kA , AIR @ 480VAC: 18kA , Circuit Breaker Type: Standard , DC Voltage Rating: 250 VDC , Depth: 3.4" , Frame Size: 150A/TED , Frame Type: TED , Height: 6.3" , Mounting: Bolt On Panelboard , Phase: 1 , Terminal Connection: Line/Load Lug , Trip Type: Thermal Magnetic , Width: 2.7"
StyleModelAIC RatingAmpsMax. Wire SizeMin. Wire SizeNumber of PolesVoltagePrice
A
TED124025WL
-258 AWG14 AWG2-£1,025.64
B
TED124015WL
-15--2-£1,025.64
A
TED124020WL
-208 AWG14 AWG2-£1,182.58
A
TED124045WL
-453 AWG (Cu), 1 AWG (Al)14 AWG (Cu), 12 AWG (Al)2-£957.24
A
TED124030WL
-308 AWG14 AWG2-£1,066.13
A
TED124060WL
-603 AWG (Cu), 1 AWG (Al)14 AWG (Cu), 12 AWG (Al)2-£987.62
A
TED124070WL
-702/0 AWG6 AWG (Cu), 4 AWG (Al)2-£1,326.62
A
TED124050WL
-50--2-£1,005.39
A
TED124040WL
-403 AWG (Cu), 1 AWG (Al)14 AWG (Cu), 12 AWG (Al)2-£1,024.21
A
TED124035WL
-353 AWG (Cu), 1 AWG (Al)14 AWG (Cu), 12 AWG (Al)2-£957.24
C
TED113Y100
14kAIC@240V100A--1277V-
RFQ
D
TED124010WL
18kAIC@480V10A--2480V£226.27
RFQ

TED Series Circuit Breakers

General Electric TED Series moulded case circuit breakers provide overcurrent and short circuit protection when used with GE panelboards. These feed-thru breakers feature a thermal magnetic trip for instantaneous and long-time overcurrent protection and a toggle actuator for manual tripping operation & indicating the status of the trip. They are equipped with line & load side lug terminals to accommodate aluminium and copper wires of sizes between 14 AWG and 2/0 AWG. Selected models feature bolt-on mounting style for installation in vertical or horizontal orientation. These TED circuit breakers are available in 277VAC & 480VAC voltage ratings on Raptor Supplies.

Features

  • General Electric TED Series circuit breakers offer a thermal-magnetic trip to provide instantaneous and long-time overcurrent protection.
  • They feature a feed-thru facility for easy mounting to switchboards & panelboards allowing quick installation.
  • These single-phase moulded case circuit breakers have load and line lugs terminals for better cable connection.
  • They are equipped with 2-poles and have amperage ratings ranging from 10A to 100A.

Standards and Approvals

  • CSA
  • UL

Frequently Asked Questions

What wire sizes can these circuit breakers accommodate?

They can accommodate wire sizes ranging from 14 to 1/0 AWG aluminium wires and 14 to 3 AWG copper wires.

What is the interrupt rating of General Electric TED Series circuit breakers?

These circuit breakers have an interrupt rating of 18kAIC at 480V.

How to maintain these circuit breakers?

  • Conduct regular visual inspections to check for loose or damaged connections.
  • Keep the circuit breakers clean by removing dirt and debris periodically.
  • Ensure terminal connections are tight and secure to prevent overheating.
  • Test the circuit breakers periodically to verify proper tripping and resetting.

We are here to help!

Looking for a part not listed here?