Auxiliary Contact Form: 1NO/1NC , Control Transformer Voltage: 208, 240, 480 VAC Primary, 120 VAC Secondary , Hz: 50/60
StyleModelNEMA Enclosure TypeAmps ACCoil VoltsOverload Relay Amp SettingPilot LightControl TransformerHP @ 3 Phase - 230VHP @ 3 Phase - 240VPrice
A
GE-CE0406HPT1
14 to 6.3120 VAC4 to 6.3AYesYes1.51.5£1,646.20
A
GE-CE0204HPT1
12.5 to 4120 VAC2.5 to 4AYesYes3/43/4£1,646.20
A
GE-CE0610HPT1
16.3 to 10120 VAC6.3 to 10AYesYes33£1,646.20
B
GE-CE0913HP1
19 to 13120 VAC9 to 13AYesNo33£969.47
A
GE-CE0913HPT1
19 to 13120 VAC9 to 13AYesYes33£1,360.50
C
GE-CE0203SSP1
11.5 to 2.5120 VAC1.5 to 2.5AYesNo1/21/2£1,068.73
D
GE-CE0203SSPT1
11.5 to 2.5120 VAC1.5 to 2.5AYesYes1/21/2£1,344.99
D
GE-CE0204SSPT1
12.5 to 4120 VAC2.5 to 4AYesYes3/43/4£1,641.91
C
GE-CE0204SSP1
12.5 to 4120 VAC2.5 to 4AYesNo3/43/4£1,068.73
C
GE-CE0406SSP1
14 to 6.3120 VAC4 to 6.3AYesNo1.51.5£1,068.73
B
GE-CE0204HP1
12.5 to 4120 VAC2.5 to 4AYesNo3/43/4£1,065.93
B
GE-CE0610HP1
16.3 to 10120 VAC6.3 to 10AYesNo33£1,068.73
A
GE-CE0203HPT1
11.5 to 2.5120 VAC1.5 to 2.5AYesYes1/21/2£1,641.91
D
GE-CE0102SSPT1
11 to 1.6120 VAC1 to 1.6AYesYes1/31/3£1,646.21
D
GE-CE0610SSPT1
16.3 to 10120 VAC6.3 to 10AYesYes33£1,646.21
B
GE-CE0406HP1
14 to 6.3120 VAC4 to 6.3AYesNo1.51.5£1,068.73
B
GE-CE0203HP1
11.5 to 2.5120 VAC1.5 to 2.5AYesNo1/21/2£1,068.73
D
GE-CE0913SSPT1
19 to 13120 VAC9 to 13AYesYes33£1,229.59
C
GE-CE0610SSP1
16.3 to 10120 VAC6.3 to 10AYesNo33£1,068.73
C
GE-CE0102SSP1
11 to 1.6120 VAC1 to 1.6AYesNo1/31/3£1,068.73
C
GE-CE0913SSP1
19 to 13120 VAC9 to 13AYesNo33£1,004.10
A
GE-CE0102HPT1
11 to 1.6120 VAC1 to 1.6AYesYes1/31/3£1,646.20
D
GE-CE0406SSPT1
14 to 6.3120 VAC4 to 6.3AYesYes1.51.5£1,641.91
B
GE-CE0102HP1
11 to 1.6120 VAC1 to 1.6AYesNo1/31/3£1,068.73
E
GE-CE1925SSP
4X19 to 2512019 to 25AYesNo7.57.5£1,162.20
F
GE-CE0406SSPT
4X4 to 6.3120 VAC4 to 6.3AYesYes1.51.5£1,156.16
F
GE-CE0102HPT
4X1 to 1.6120 VAC1 to 1.6AYesYes1/31/3£1,120.75
E
GE-CE1420SSP
4X14 to 2012014 to 20AYesNo55£1,146.66
E
GE-CE1116SSP
4X11 to 1612011 to 16AYesNo55£1,146.66
E
GE-CE0102SSP
4X1 to 1.61201 to 1.6AYesNo1/31/3£946.83
E
GE-CE1925SSPT
4X19 to 25120 VAC19 to 25AYesYes7.57.5£1,255.01
F
GE-CE2432HPT
4X24 to 32120 VAC24 to 32AYesYes1010£1,255.01
F
GE-CE1420HPT
4X14 to 20120 VAC14 to 20AYesYes55£1,360.51
F
GE-CE0203HPT
4X1.5 to 2.5120 VAC1.5 to 2.5AYesYes1/21/2£1,120.75
F
GE-CE0203SSPT
4X1.5 to 2.5120 VAC1.5 to 2.5AYesYes1/21/2£1,158.82
E
GE-CE1116SSPT
4X11 to 16120 VAC11 to 16AYesNo55£1,255.01
F
GE-CE0913SSPT
4X9 to 13120 VAC9 to 13AYesYes33£957.70
F
GE-CE0913HPT
4X9 to 13120 VAC9 to 13AYesYes33£1,118.16
F
GE-CE0406HPT
4X4 to 6.3120 VAC4 to 6.3AYesYes1.51.5£1,120.75
F
GE-CE1116HP
4X11 to 16120 VAC11 to 16AYesNo55£1,004.08
F
GE-CE1116HPT
4X11 to 16120 VAC11 to 16AYesYes55£1,255.01
E
GE-CE0913SSP
4X9 to 131209 to 13ANoNo33£977.51
F
GE-CE0204HP
4X2.5 to 4120 VAC2.5 to 4AYesNo3/43/4£958.19
F
GE-CE0610HP
4X6.3 to 10120 VAC6.3 to 10AYesNo33£1,036.01
F
GE-CE0102SSPT
4X1 to 1.6120 VAC1 to 1.6AYesYes1/31/3£1,256.23
F
GE-CE0204HPT
4X2.5 to 4120 VAC2.5 to 4AYesYes3/43/4£1,120.75
F
GE-CE0610HPT
4X6.3 to 10120 VAC6.3 to 10AYesYes33£1,120.75
F
GE-CE1925HP
4X19 to 25120 VAC19 to 25AYesNo7.57.5£1,004.09
F
GE-CE0204SSPT
4X2.5 to 4120 VAC2.5 to 4AYesYes3/43/4£1,158.82
F
GE-CE2432HP
4X24 to 32120 VAC24 to 32AYesNo1010£1,004.10
F
GE-CE1925HPT
4X19 to 25120 VAC19 to 25AYesYes7.57.5£1,441.06
E
GE-CE1420SSPT
4X14 to 20120 VAC14 to 20AYesNo55£1,255.01
F
GE-CE0102HP
4X1 to 1.6120 VAC1 to 1.6AYesNo1/31/3£1,038.73
F
GE-CE0203HP
4X1.5 to 2.5120 VAC1.5 to 2.5AYesNo1/21/2£1,036.01
F
GE-CE0406HP
4X4 to 6.3120 VAC4 to 6.3AYesNo1.51.5£955.91
F
GE-CE1420HP
4X14 to 20120 VAC14 to 20AYesNo55£926.24
F
GE-CE0610SSPT
4X6.3 to 10120 VAC6.3 to 10AYesYes33£1,158.82
E
GE-CE2432SSPT
4X24 to 32120 VAC24 to 32AYesNo1010£1,366.71
F
GE-CE0913HP
4X9 to 13120 VAC9 to 13AYesNo33£883.25
E
GE-CE2432SSP
4X24 to 3212024 to 32AYesNo1010£1,168.03

Working Mechanism

  • When the start button is pressed, it sends a signal to the contactor coil, which is an electromagnetic switch.
  • The contactor coil becomes energised and generates a magnetic field, causing the contactor contacts to close. These contacts connect the motor to the power supply.
  • With the contacts closed, electrical power flows to the motor, initiating its rotation.

Features

  • They feature a robust enclosure with a NEMA rating, ensuring protection against environmental factors such as dust, moisture and corrosive substances.
  • These IEC combination starters have operator selector switches, allowing users to easily choose between different operational modes, such as Hand, Off or Auto, providing control and flexibility.
  • They are equipped with pilot lights incorporating pilot lights that indicate the equipment's operational status and simplify troubleshooting by quickly identifying the equipment's condition.

Standards and Approvals

  • UL
  • CSA

Frequently Asked Questions

What does IEC stand for?

The IEC stands for International Electrotechnical Commission. It establishes the global standard for electric motors, providing a framework that is similar to other international standards organisations.

What is the difference between a combination starter and a motor starter?

Combination motor starters offer an efficient solution by consolidating both the motor starter and electrical protection devices within a single enclosure. These starters are specifically designed to ensure user safety while enabling the convenient starting and stopping of a motor using an electromechanical switch.

What maintenance tasks are necessary to prolong the lifespan of General Electric IEC combination starters?

Regularly inspect and tighten connections, replace worn components and perform thermal inspections to identify potential issues proactively.

How can I determine the appropriate size of an IEC motor starter for my motor?

While choosing make sure that the specifications such as motor's full load current (FLC), starting current and voltage. Consult the manufacturer's sizing charts and recommendations for accurate selection.

We are here to help!

Looking for a part not listed here?