-
Change Country
- Sign in
- Submit RFQ
Eaton HFWF Series molded case circuit breakers (MCCBs) are used for protecting electrical systems against overloads and short circuits, ensuring the safety of personnel and equipment.
Style | Model | Price | |
---|---|---|---|
A | HFWF3063VL | £3,859.26 | RFQ
|
B | HFWF1016L | £1,005.40 | RFQ
|
C | HFWF2016L | £2,995.91 | RFQ
|
B | HFWF1160VL | £3,224.65 | RFQ
|
B | HFWF1125VL | £1,505.33 | RFQ
|
B | HFWF1100VL | £1,505.33 | RFQ
|
B | HFWF1100L | £1,505.33 | RFQ
|
C | HFWF2020VL | £2,995.91 | RFQ
|
B | HFWF1080VL | £927.91 | RFQ
|
B | HFWF1063L | £927.91 | RFQ
|
B | HFWF1032VL | £1,005.40 | RFQ
|
B | HFWF1032L | £1,005.40 | RFQ
|
B | HFWF1063VL | £927.91 | RFQ
|
C | HFWF2020L | £2,995.91 | RFQ
|
B | HFWF1025L | £1,005.40 | RFQ
|
B | HFWF1050L | £1,341.15 | RFQ
|
B | HFWF1040VL | £1,005.40 | RFQ
|
B | HFWF1050VL | £1,341.15 | RFQ
|
B | HFWF1020L | £1,005.40 | RFQ
|
B | HFWF1020VL | £1,005.40 | RFQ
|
B | HFWF1016VL | £1,005.40 | RFQ
|
A | HFWF3080VD14Z04 | £4,709.71 | RFQ
|
A | HFWF3080D17 | £4,709.71 | RFQ
|
A | HFWF3063V | £4,292.78 | RFQ
|
B | HFWF1160L | £3,224.65 | RFQ
|
C | HFWF2032VL | £2,995.91 | RFQ
|
A | HFWF3050L | £3,859.26 | RFQ
|
A | HFWF3175D17 | £10,247.70 | RFQ
|
A | HFWF3200V | £11,345.34 | RFQ
|
A | HFWF3040VL | £3,859.26 | RFQ
|
D | HFWF4032L | £6,504.66 | RFQ
|
A | HFWF3040L | £3,859.26 | RFQ
|
A | HFWF3175V | £11,345.34 | RFQ
|
A | HFWF3040D17 | £3,859.26 | RFQ
|
D | HFWF4016L | £6,504.66 | RFQ
|
A | HFWF3040VD14Z04 | £3,859.26 | RFQ
|
A | HFWF3225V | £11,345.34 | RFQ
|
A | HFWF3025V | £3,193.30 | RFQ
|
A | HFWF3020VL | £3,859.26 | RFQ
|
C | HFWF2016VL | £2,995.91 | RFQ
|
A | HFWF3160VD14Z04 | £10,247.70 | RFQ
|
A | HFWF3020VD14Z04 | £3,859.26 | RFQ
|
A | HFWF3160L | £10,247.70 | RFQ
|
A | HFWF3016VD14Z04 | £3,859.26 | RFQ
|
A | HFWF3125VD14Z04 | £10,441.39 | RFQ
|
C | HFWF2160L | £9,087.34 | RFQ
|
A | HFWF3125V | £11,566.71 | RFQ
|
C | HFWF2025L | £2,995.91 | RFQ
|
A | HFWF3100VL | £4,709.71 | RFQ
|
C | HFWF2050VL | £2,995.91 | RFQ
|
A | HFWF3080VL | £4,709.71 | RFQ
|
A | HFWF3063L | £3,859.26 | RFQ
|
A | HFWF3050VL | £3,859.26 | RFQ
|
A | HFWF3100D17 | £4,665.42 | RFQ
|
C | HFWF2080VL | £2,995.91 | RFQ
|
A | HFWF3040V | £4,292.78 | RFQ
|
A | HFWF3225VL | £10,247.70 | RFQ
|
A | HFWF3032L | £3,859.26 | RFQ
|
A | HFWF3175L | £10,247.70 | RFQ
|
A | HFWF3020L | £3,859.26 | RFQ
|
A | HFWF3160VL | £10,247.70 | RFQ
|
A molded case houses the internal components of the circuit breaker, including the trip unit, contacts and operating mechanism. It is made of a high-strength, non-conductive material that provides insulation and protection to the components of a circuit breaker.
The circuit breaker can be easily reset by moving the toggle handle to the extreme OFF position and then to the ON position to restore the current. However, during a thermal trip, the circuit breaker cannot be reset until the thermal element (bi-metallic strip) cools down.
The PUSH-TO-TRIP button is used for periodically exercising the operating mechanism and checking the proper functioning of the trip unit.