EATON GD Series Complete Molded Case Circuit Breakers, G Frame

Eaton GD Series moulded case circuit breakers reduce risks of damage by fault currents and fatal electrical shocks.

Filter
Frame Type: GD , Voltage: 480V
StyleModelAIC RatingAmpsNumber of PolesPrice
A
GD3090S1
---£3,945.95
RFQ
B
GD3020DV
---£1,606.79
RFQ
A
GD3090DS3
---£3,962.57
RFQ
A
GD3090A3
---£2,940.57
RFQ
C
GD3100A3
---£2,927.64
RFQ
C
GD3100DS4
---£3,945.95
RFQ
B
GD3020A3S7
---£4,213.46
RFQ
B
GD3020DB3
---£2,499.66
RFQ
B
GD3020
---£557.28
RFQ
B
GD3020DS1
---£3,495.84
RFQ
B
GD3020D
---£1,606.79
RFQ
D
GD3070S3
---£2,840.95
RFQ
B
GD3020S1
---£3,423.89
RFQ
E
GD3025A3
---£2,499.66
RFQ
E
GD3025C
---£1,606.79
RFQ
F
GD3030CA3
---£2,451.69
RFQ
E
GD3025CA3
---£2,451.69
RFQ
E
GD3025S1
---£3,423.89
RFQ
F
GD3030A3
---£2,527.33
RFQ
E
GD3025S2
---£3,423.89
RFQ
G
GD3080C
---£1,970.21
RFQ
D
GD3070A3
---£2,940.57
RFQ
E
GD3025D
---£1,606.79
RFQ
B
GD3020DA3
---£2,499.66
RFQ
H
GD3015A3
---£2,527.33
RFQ
H
GD3015DB3
---£2,387.13
RFQ
H
GD3015DA3
---£2,499.66
RFQ
H
GD3015D
---£1,606.79
RFQ
H
GD3015S114
---£4,278.02
RFQ
B
GD3020C
---£1,606.79
RFQ
B
GD3020CA3
---£2,499.66
RFQ
I
GD3015DS1
---£3,495.84
RFQ
F
GD3030S1
---£3,423.89
RFQ
J
GD3060A3S7
---£4,213.46
RFQ
K
GD3035C
---£1,606.79
RFQ
L
GD3040C
---£1,606.79
RFQ
L
GD3040DA3
---£2,499.66
RFQ
M
GD3045A3
---£2,499.66
RFQ
N
GD3050A3
---£2,527.33
RFQ
N
GD3050A3S7
---£4,213.46
RFQ
J
GD3060C
---£1,568.06
RFQ
J
GD3060G2
---£1,634.48
RFQ
F
GD3030A3S7
---£4,213.46
RFQ
E
GD3025DA3
---£2,499.66
RFQ
O
GD2050DV
---£1,606.79
RFQ
A
GD3090D
---£2,045.84
RFQ
K
GD3035A3
---£2,527.33
RFQ
L
GD3040DV
---£1,920.41
RFQ
M
GD3045S1
---£3,423.89
RFQ
P
GD3050C
---£1,606.79
RFQ
J
GD3060D
---£1,606.79
RFQ
D
GD3070S1
---£3,945.95
RFQ
G
GD3080S3
---£3,945.95
RFQ
J
GD3090D1S3
---£3,962.57
RFQ
G
GD3080S4
---£3,945.95
RFQ
C
GD3100S4
---£3,896.15
RFQ
K
GD3035
---£571.09
RFQ
L
GD3040DS101
---£3,296.60
RFQ
P
GD3050DV
---£1,606.79
RFQ
P
GD3050DS101
---£3,296.60
RFQ
J
GD3060S1
---£3,423.89
RFQ

Working Mechanism

  • Eaton GD Series moulded case circuit breakers feature fixed thermal and fixed magnetic trips to protect against faulty currents:

Fixed Thermal Trips

  • The thermal trip consists of a bimetallic strip which gets heated and bends when an overcurrent passes through the conductors, which opens the contacts and interrupts the current flow.

Fixed Magnetic Trips

  • The magnetic trip has an electromagnetic component that detects the presence of short circuits in a circuit.
  • As the current rises, a magnetic field is generated that trips the breaker and causes the contacts to open and stop the current flow.

Features

  • These units feature a fixed thermal and fixed magnetic trip unit to avoid nuisance tripping in mild current fluctuation but are highly sensitive to heavy inrush current, thus producing both instantaneous and time-delayed current limiting protection.
  • They have a compact, space-saving design that provides installation in tight spaces and allows for high-speed blow-open action, resulting in superior performance.
  • They are integrated with line and load side terminals for easy installation with panelboards and load centres.
  • These MCCBs also include a toggle and a mechanical latching mechanism that ensures the circuit breaker remains in the tripped position until it is manually reset.

Standards and Approvals

  • UL

Frequently Asked Questions

What is the advantage of moulded cases?

Moulded cases hold current-carrying components, trip devices and mechanisms integrated into one unit.

What is the purpose of a G-frame?

A G-frame is a modular design that provides a versatile and flexible platform to accommodate low-voltage circuit breakers. They also protect electrical systems from damage caused by overloads and short circuits, as well as mechanical stress.

What is the purpose of a toggle?

These circuit breakers come with an integrated over-centre toggle for visual indication of tripped status.

We are here to help!

Looking for a part not listed here?