Change Country
- Sign in
- Submit RFQ
Eaton G Series molded case circuit breakers (MCCBs) are used in switchboards, panelboards, motor control centres and electrical distribution equipment for protection against overloads, short circuits and electrical faults.
Style | Model | AIC Rating | Amps | Price | |
---|---|---|---|---|---|
A | EGE3050FFEA1 | - | - | £2,304.13 | RFQ
|
B | EGB3063FFG | - | - | £1,446.29 | RFQ
|
C | EGB4015FFG | - | - | £1,868.75 | RFQ
|
B | EGB3125FFGV | - | - | £3,492.16 | RFQ
|
B | EGB3090FFWH31 | - | - | £1,579.12 | RFQ
|
B | EGB3090FFB | - | - | £1,658.44 | RFQ
|
B | EGB3100FFGA3 | - | - | £2,390.82 | RFQ
|
B | EGB3080AFG | - | - | £1,700.87 | RFQ
|
B | EGB3080FFGA1 | - | - | £2,390.82 | RFQ
|
B | EGB3070FFWH31 | - | - | £1,579.12 | RFQ
|
B | EGB3070FFG | - | - | £837.09 | RFQ
|
B | EGB3070FFWX8Y1 | - | - | £1,857.68 | RFQ
|
D | EGB7040AFGV | - | - | £1,913.02 | RFQ
|
B | EGB3070FFB | - | - | £1,658.44 | RFQ
|
B | EGB3070FFGV | - | - | £1,658.44 | RFQ
|
B | EGB3063FFGV | - | - | £1,446.29 | RFQ
|
B | EGB3060FFGH31 | - | - | £1,376.19 | RFQ
|
B | EGB3050FFWZ90 | - | - | £1,830.01 | RFQ
|
B | EGB3060FFG | - | - | £802.10 | RFQ
|
B | EGB3050FFWV | - | - | £1,409.40 | RFQ
|
B | EGB3060FFWX8Y1 | - | - | £1,560.67 | RFQ
|
B | EGB3050AFG | - | - | £1,494.26 | RFQ
|
E | EGB7016FFG | - | - | £1,868.75 | RFQ
|
E | EGB7050FFG | - | - | £1,868.75 | RFQ
|
B | EGB3045FFB | - | - | £1,446.29 | RFQ
|
F | GEE3045FFM | - | - | £1,492.43 | RFQ
|
G | EGB1050FFB | - | - | £597.70 | RFQ
|
G | EGB1030FFB | - | - | £597.70 | RFQ
|
H | GES7100FFM | - | - | £2,527.33 | RFQ
|
H | GES7160AFM | - | - | £5,868.21 | RFQ
|
H | GES7090FFM | - | - | £2,527.33 | RFQ
|
H | GES7070FFM | - | - | £2,527.33 | RFQ
|
H | GES7110FFM | - | - | £5,687.42 | RFQ
|
I | GEE4020AFM | - | - | £2,067.99 | RFQ
|
F | GEE3125AFM | - | - | £4,178.40 | RFQ
|
F | GEE3020FFM | - | - | £1,492.43 | RFQ
|
E | EGB7125FFGV | - | - | £1,868.75 | RFQ
|
F | GEE3025FFM | - | - | £1,492.43 | RFQ
|
J | GEB7160AFM | - | - | £4,545.51 | RFQ
|
J | GEB7125AFM | - | - | £4,545.51 | RFQ
|
J | GEB7160FFM | - | - | £4,401.62 | RFQ
|
F | GEE3015FFM | - | - | £1,492.43 | RFQ
|
F | GEE3016FFM | - | - | £1,492.43 | RFQ
|
J | GEB7080AFM | - | - | £2,169.45 | RFQ
|
J | GEB7080FFM | - | - | £2,091.98 | RFQ
|
J | GEB7025AFM | - | - | £1,804.19 | RFQ
|
J | GEB7015FFM | - | - | £1,758.06 | RFQ
|
B | EGB3045FFG | - | - | £802.10 | RFQ
|
B | EGB3050FFB | - | - | £1,446.29 | RFQ
|
G | EGB1100FFG | - | - | £654.89 | RFQ
|
K | GEE7025AFM | - | - | £2,067.99 | RFQ
|
K | GEE7110FFM | - | - | £5,399.63 | RFQ
|
K | GEE7080AFM | - | - | £2,492.29 | RFQ
|
K | GEE7125AFM | - | - | £5,565.67 | RFQ
|
K | GEE7063AFM | - | - | £2,067.99 | RFQ
|
K | GEE7050FFM | - | - | £2,001.58 | RFQ
|
K | GEE7032AFM | - | - | £2,067.99 | RFQ
|
K | GEE7040AFM | - | - | £2,067.99 | RFQ
|
K | GEE7040FFM | - | - | £2,001.58 | RFQ
|
K | GEE7015FFM | - | - | £2,001.58 | RFQ
|
I | GEE4125AFM | - | - | £5,554.59 | RFQ
|
While installing, it is important to turn off the power to the panelboard or other electrical equipment where it will be installed. The cover of the equipment must be removed, and any wires or cables that are attached to the existing breaker must be disconnected. The new breaker can then be installed by attaching it to the equipment and reconnecting the wires or cables. After the installation, replace the cover and restore power to the equipment.
If these circuit breakers continue to trip, this could be a sign of an overload or short circuit within the electrical system. To resolve this issue, it is recommended to inspect all wires and cables for any signs of looseness or damage. Additionally, make sure the circuit breaker is appropriately sized for the load it is intended to protect.