Sign In

EATON CL Type Thermal Magnetic Circuit Breakers

Eaton CL Series thermal magnetic circuit breakers prevent overcurrents, short circuits and ground faults. They are typically used in commercial and industrial applications like electrical panels, ...Read More

Filter
StyleModelNumber Of PolesCircuit Breaker TypeVoltagePrice
A
CL120
1CH120/240V£15.21
B
CL125
1CH120/240V£17.76
C
CL130CS
1CH120/240V£13.46
D
CL115GFCS
1CH120/240V£166.24
D
CL120GFCS
1CH120/240V£162.96
E
CL115
1CH120/240V£15.21
F
CL115CS
1CH120/240V£13.46
G
CL140CS
1CH120/240V£87.65
H
CL150
1CH120/240V£17.76
I
CL130GF
1CH120/240V-
RFQ
J
CL150CS
1CH120/240V£87.65
K
CL145
1CH120/240V-
RFQ
L
CL130
1CH120/240V£15.21
M
CL135
1CH120/240V£70.60
N
CL115GF
1CH120/240V£137.68
O
CL140
1CH120/240V£24.48
P
CL250CS
2CH120/240V£35.88
Q
CL250
2CH120/240V£39.47
R
CL230CS
2CH120/240V£30.93
S
CL245
2CH120/240V£44.57
T
CL235
2CH120/240V£44.57
U
CL230
2CH120/240V£39.04
V
CL220CS
2CH120/240V£30.44
W
CL215
2CH120/240V£39.04
X
CL215CS
2CH120/240V-
RFQ
Y
CL240
2CH120/240V£39.47
Z
CL225
2CH120/240V£44.57
A1
CL220
2CH120/240V£39.04
B1
CL240CS
2CH120/240V£33.25

Working Mechanism

  • The circuit breaker has a bimetal strip and an electromagnet to help with tripping conditions and protect against fire hazards.
  • The bimetallic strip gets heated and bends when a constant overcurrent passes through the device.
  • In such conditions, the mechanical latch (in the circuit breaker) opens the contacts, interrupting the current flow in the circuit.
  • During short circuits, the current rises abruptly, causing the electromagnetic displacement of the plunger in the tripping coil or solenoid.
  • The plunger strikes the trip lever, releasing the latch mechanism and opening the contacts again.

Frequently Asked Questions

How do I reset my circuit breaker after it trips?

Turn the handle to the 'ON' position to retract the current flow in the circuit, thereby resetting the breaker.

What is the difference between non-interchangeable and interchangeable circuit breakers?

  • The entire breaker must be changed when the trip unit in non-interchangeable or fixed breakers needs to be replaced.
  • In interchangeable breakers, only the trip unit needs to be replaced without dismantling the device.

What is the purpose of a toggle handle?

When there is a surge of overcurrent, short circuit or under voltage release, the toggle handle snaps into the TRIPPED position to indicate that the breaker has tripped. The toggle handle can be brought back to the OFF position (RESET) to restore the current.

We are here to help!