EATON BABRSP Series Smart Circuit Breakers

Eaton BABRSP Series smart circuit breakers are advanced circuit protection devices used in industrial and commercial settings to improve system reliability, energy efficiency and safety. They allow ...Read More

Filter
StyleModelPrice
A
BABRSP2015X36
£1,558.84
RFQ
B
BABRSP1025X72
£1,062.59
RFQ
B
BABRSP1030
£331.52
RFQ
B
BABRSP1015X72
£946.36
RFQ
B
BABRSP1020X72
£833.83
RFQ
A
BABRSP2020X36
£1,411.25
RFQ
A
BABRSP2025
£1,794.95
RFQ
A
BABRSP2030
£780.98
RFQ
A
BABRSP2020
£780.98
RFQ
B
BABRSP1025
£1,062.59
RFQ
B
BABRSP1020
£317.05
RFQ
B
BABRSP1030X72
£1,129.01
RFQ
A
BABRSP2030X36
£1,942.54
RFQ
B
BABRSP1015
£317.05
RFQ
A
BABRSP2015
£780.98
RFQ
A
BABRSP2025X36
£1,794.95
RFQ

Working Mechanism

  • These circuits protect electrical systems from damage due to overcurrents, short circuits or other electrical faults.
  • To do so, they use advanced electronics and algorithms to monitor the current and voltage in real-time.
  • The breaker compares the actual current to the set current limit. If it exceeds the limit, the breaker trips and interrupts the current flow.
  • Additionally, they come with data logging and communication settings, which allow them to collect and transmit information about the system's performance and status.

Frequently Asked Questions

What is the purpose of thermal overload protection?

Thermal overload protection in a circuit breaker is a safety feature that allows protection from excessive heat generated by the current flow. The protector monitors the temperature of the device if the temperature exceeds a certain threshold due to the usage of a bimetallic strip (a type of thermostat) that changes shape when it gets hot and trips the breaker, thus shutting off the power to the device.

What is an arc chute assembly?

An arc chute assembly is a component designed to control and extinguish arcs that may occur during the operation. It consists of metal plates, known as arc runners and arc contacts, arranged in a specific pattern to create a path for the arc to flow. When the circuit breaker interrupts the current flow, an arc is created which is then guided by the arc chute assembly to move along a pre-determined path, thus preventing the device from damage.

What is the use of a mechanical trip indicator?

A mechanical trip indicator is used for indicating when the device has tripped due to an electrical fault or other abnormal condition. It features a flag or lever that moves to a different position when the device has been tripped and indicates the status of the device.