Schneider Electric manual motor starters switch power to a motor while protecting it from faults. They are useful in manufacturing, agriculture, mining and construction applications.
SCHNEIDER ELECTRIC -

Manual Motor Switches

StyleModelItemPrice (inc. VAT)
AVZ18Extension Kit£74.44
AVZ31Extension Kit£76.11
BGV2ME143Manual Motor Switch£298.95
CGV2G354Manual Motor Switch£47.51
DGP2E06Manual Motor Switch£100.26
EGP2E14Manual Motor Switch£107.69
FGP2E16Manual Motor Switch£107.69
GGP2E20Manual Motor Switch£107.69
HGP2E03Manual Motor Switch£100.26
IGV2K04Manual Motor Switch£196.77
BGV2G254Manual Motor Switch£36.53
JGV2GH7Manual Motor Switch£26.15
BGV1G02Manual Motor Switch£23.46
KGP2E02Manual Motor Switch£100.26
LGV2E01Manual Motor Switch£19.16
MGV2ME163Manual Motor Switch£376.66
BGV2RT08Manual Motor Switch£317.13
BGV2ME103Manual Motor Switch£323.87
NGV3P25Manual Motor Switch£755.74
OGP2E01Manual Motor Switch£100.26
PGP2E22Manual Motor Switch£128.11
QGP2E05Manual Motor Switch£100.26
BGV2RT07Manual Motor Switch£324.73
NGV3P32Manual Motor Switch£752.38
BGV3P18Manual Motor Switch£605.43
SCHNEIDER ELECTRIC -

Manual Motor Starters

StyleModelHP @ 3 Phase - 575VAmps ACDepthOverload Relay Amp SettingPilot LightWidthHeightHP @ 1 Phase - 120VPrice (inc. VAT)
AGV2P04--3.83"0.4 to 0.63AYes1.75"3.5"-£430.23
BGV2ME01-48 to 653.03"0.1 to 0.16AYes1.75"3.5"-£264.48
BGV2ME04-0.40 to 0.632.6"0.4 to 0.63ANo1.75"3.5"-£284.23
CGV2ME03-0.25 to 0.402.6"0.25 to 0.4AYes1.75"3.5"-£262.62
AGV2P01--3.83"0.1 to 0.16ANo1.75"3.5"-£393.06
AGV2P03-15 to 253.83"0.25 to 0.4ANo1.75"3.5"-£391.12
AGV2P02--3.83"0.16 to 0.25ANo1.75"3.5"-£403.07
BGV2ME02-60 to 1003.03"0.16 to 0.25ANo1.75"3.5"-£257.49
AGV2P061-3.83"1 to 1.6AYes1.75"3.5"-£382.94
BGV2ME0611 to 1.62.6"1 to 1.6ANo1.75"3.5"-£321.33
AGV2P071.5-3.83"1.6 to 2.5AYes1.75"3.5"-£353.95
BGV2ME071.51.6 to 2.52.6"1.6 to 2.5AYes1.75"3.5"-£297.24
AGV2P051/2-3.83"0.63 to 1ANo1.75"3.5"-£402.58
BGV2ME051/20.63 to 1.002.6"0.63 to 1AYes1.75"3.5"-£313.04
AGV2P083-3.83"2.5 to 4AYes1.75"3.5"1/8£354.96
BGV2ME0832.5 to 42.6"2.5 to 4ANo1.75"3.5"1/8£303.74
BGV2ME1054 to 6.32.6"4 to 6.3ANo1.75"3.5"1/4£299.22
AGV2P105-3.83"4 to 6.3AYes1.75"3.5"1/4£354.66
BGV2ME147.56 to 102.6"6 to 10ANo1.75"3.5"1/2£312.57
AGV2P147.5-3.83"6 to 10AYes1.75"3.5"1/2£417.66
BGV2ME16109 to 142.6"9 to 14ANo1.75"3.5"3/4£379.75
DGV3P13109 to 134.4"9 to 13ANo2.4"4.7"1£720.16
BGV2ME201013 to 182.6"13 to 18ANo1.75"3.5"1£397.53
AGV2P1610-3.83"9 to 14AYes1.75"3.5"3/4£464.04
AGV2P2015-3.83"13 to 18AYes1.75"3.5"1£463.73

Features

  • Schneider manual motor starters prevent the motor from drawing a large amount of starting current.
  • They ensure smooth starting by controlling torque for slow acceleration, thereby reducing jerks.
  • These starters avoid short-circuit and overload problems.
  • They shut down the motor automatically when the power source is turned off.

Working Mechanism

  • Schneider motor starters comprise two devices: a contractor and an overload relay.
  • The contractor completes the circuit to the motor, and the overload relay keeps track of how much current the motor is using.
  • Their overload protection mechanism regulates the maximum load the motor may safely bear.
  • When the motor exceeds its maximum capacity, these starters open the motor starting control circuit and turn the motor off.

Standards and Approvals

  • UL
  • CSA
  • CE

Frequently Asked Questions

What is the difference between a manual motor starter and an automatic motor starter?

A manual motor starter requires manual intervention to start and stop the motor, while an automatic motor starter can automatically start and stop the motor based on preset conditions or control signals.

Can I automate Schneider manual motor starters?

Yes, you can integrate these motor starters with programmable logic controllers (PLCs) or other control devices for automated operation and remote monitoring.

What is the difference between a motor starter and a motor contactor?

A motor starter includes a motor contactor as one of its components. The motor contactor is responsible for opening and closing the electrical circuit to start or stop the motor, while the starter also includes overload protection and control components.