Circuit Breakers, CHB Series, Bolt-On Mount(3 Products)
EATON
| Number Of Poles | Height | Wire Size | Circuit Breaker Type | Voltage Rating | Type | Price |
|---|---|---|---|---|---|---|
| 1 | 39" | #14 AWG to 8 AWG | Chb | 120/240V | - | £363.92 |
| 2 | 2" | #14 AWG to 8 AWG | Chb | 120/240V | Circuit Breaker | £773.02 |
| 2 | 2" | #8 AWG to 4 AWG | Chb | 120/240V | Circuit Breaker | RFQ |
Description
Working Mechanism
- Eaton CHB Series circuit breakers normally allow current to flow. In this state, the current-carrying contacts come into contact with each other.
- A ground fault can be caused by faulty wiring, damaged appliances or worn insulation.
- When this device detects a ground fault, the contacts move apart, thus tripping the circuit.
- After troubleshooting the issue, users can turn the circuit back ON by resetting it.
Features
- The handles of these breakers are marked with ON/OFF indication & current rating.
- They come with standard box lug terminals that are capable of accommodating copper and aluminium wire sizes ranging from 14 to 8 AWG.
- They have a thermal-magnetic trip for avoiding nuisance tripping during mild overloads but reacting instantly to severe short circuits.
- Selected models have an internal common trip connection to operate all poles simultaneously.
- These units feature 5mA ground fault protection to prevent fatal electrical shocks caused due to overload and short-circuit occurrences.
- They feature a bolt-on mounting system that is equipped with brackets for secure installation.
Frequently Asked Questions
Q. Where can we use CHB Series Eaton circuit breakers?
A. These circuit breakers protect against high-frequency ground faults in heating, air conditioning and refrigeration equipment.
Q. Are these units suitable for reverse feed applications?
A. These circuit breakers feature interrupting capacity of 10kA at 240V, making them ideal for reverse feed applications.
Q. How to install a circuit breaker?
A.
- Remove the panel cover. Use a screwdriver to unscrew all four edges of the panel cover while holding it tight, to prevent it from slipping off.
- Connect the neutral and ground wires.
- Place the breaker inside.
- Screw the panel cover back.
Q. Does Raptor Supplies offer similar Eaton breaker variants with a higher amperage rating?
A. Yes, Raptor Supplies offers Eaton CHB230GF circuit breaker having an amperage rating of 500A.
Explore More
- KEYSHAFT
- NORGREN
- SUPERIOR
- SECURITECH
- CARCO
- Cordless Cable Cutters
- Hazardous Location Electrical Boxes
- Modular Pipe and Rail Fittings
- Solenoid Valve Accessories
- Tubing Racks
- HELICOIL Spiral Point Plug Taps, 5H, Metric Coarse
- ML KISHIGO 3700 Series Incident Command Vests
- DESTACO 817 Series Pneumatic Toggle Clamps
- ABUS Lockout Padlock, Keyed Different
- GLOBE SCIENTIFIC Diamond RealSeal Bottles, Narrow Mouth, HDPE
- SALSBURY INDUSTRIES Horizontal MailBoxes
- MOLDED FIBERGLASS N/S Container Lids
- WEG CSW30 Series Potentiometers
- BROWNING Q-D Sheaves For 5V Belts, 2 Grooves
- QMARK Fan Blades