SQUARE D BDL36030 Molded Case Circuit Breaker, 30A, Number Of Poles 3, Series Bdl

Item: CE6GYW
Model: BDL36030
50 In Stock

Ships within 2 days via

We deliver to your doorstep under DAP terms. Customs clearance is for your account

£1183.5
5.00% off
£1124.33/unit
Trade Prices Available
Request Quote

Payment

Delivery

Specifications

Item Circuit Breaker
Ac Voltage Rating 525V AC
Actuator Type Toggle
Ambient Air Temp. For Operation -13°F to +158°F
Ambient Air Temp. For Storage -58°F to +185°F
Amps 30A
Awg Gauge 6 AWG to 2/0 AWG, 14 AWG to 3/0 AWG
Breaking Capacity 25 kA 208Y/120V AC 50/60 Hz UL 489, 25 kA 240V AC 50/60 Hz UL 489, 18 kA 480/277V AC 50/60 Hz UL 489, 18 kA 480V AC 50/60 Hz UL 489, 14 kA 600Y/347V AC 50/60 Hz UL 489, 10 kA 250V DC UL 489
Breaking Capacity Code D
Circuit Breaker Actuator Toggle
Circuit Breaker Application HACR Rated
Circuit Breaker Mounting Style Unit Mount
Circuit Breaker Type Standard
Color Gray
Component Type Circuit Breaker
Connection Pitch 1.06"
Continuous Amps Rating 80%
Control Type Toggle
Dc Voltage Rating Not Rated
Depth 3.1"
Device Application Distribution
Electrical Connection Everlink Lug, Line, Load
Electrical Durability 10000 Cycles
For Use With Electrical Distribution Equipment, Industrial Control Panels
Frame 125A/BD
Frame Type BDL
Height 5 2/5" , 5.39"
Ik Degree Of Protection IK07
Instantaneous Trip Fixed
Ip Degree Of Protection IP40
Line Rated Amps 30A
Local Signalling Presence Of Auxiliary Contacts Flag Green
Max. Air Rating 25 kA At 277/408V AC
Max. Operating Temp. 158°F
Maximum Wire Size 2 AWG, 3 AWG
Mechanical Durability 20000 Cycles
Min. Operating Temp. -13°F
Min. Wire Size 6 AWG, 14 AWG
Mounting Mode Clip On 35 mm x 15 mm Symmetrical Din Rail, By Screws Plate
Mounting Style Unit
Network Frequency 50/60 Hz
No. Of 9 Mm Pitches 9
No. Of Poles 3
Number Of Poles 3
Number Of Slots 3
Operating Altitude 0 ft. to 6561.68 ft. Without Derating, 5000m With Derating
Phase 3
Phase Connection ABC
Pollution Degree 3 IEC 60947-1
Power Wire Stripping Length 0.8"
Quality Labels ce.png
Quantity Per Set Set of 1
Rated Impulse Withstand Voltage 8 kV
Rated Insulation Voltage 800V
Rated Operational Voltage 525V
Rated Service Breaking Capacity 25 kA @ 220-240V AC @ 50/60 Hz, 14 kA @ 500-525V AC @ 50/60 Hz, 18 kA @ 380-415V AC @ 50/60 Hz, 18 kA @ 440V AC @ 50/60 Hz
Returnability Yes
Suitability For Isolation Yes, IEC 60947-2
Terminal Connection Everlink Lug Both Ends
Tightening Torque 44.3 lbf.in. @ 0.004 sq. in. to 0.02 sq. in. @ 14 AWG to 4 AWG, 79.7 lbf.in. @ 0.04 sq. in. to 0.1 sq. in. @ 3 AWG to 3/0 AWG
Trip Type Thermal Magnetic
Trip Unit Technology Thermal-Magnetic
Utilisation Category Category A
Voltage 600V
Voltage Type AC
Width 3.19" , 3.2"
standard CSA C22.2 NO 5, EN/IEC 60947-2, EN/IEC 60947-5-1, GB 14048.2, NEMA AB1, NMX J-266, UL 489

Product Details

    • Square D BDL36030 circuit breaker designed for preventing short-circuit and current overload conditions to protect industrial machinery & sensitive electrical circuits
    • Thermal-magnetic trip unit for responding against severe power surges at once while avoiding tripping on mild overloads
    • Line- and load-side lug terminals and clip-on DIN rail mounting design for ease-of-wiring and ease-of-installation, respectively
    • Supports 6 - 2 AWG fine-stranded and 14 - 3 AWG rigid aluminium / copper wires
    • CSA-certified, CE-marked, UL-listed and IEC-approved

Shipping Information

height 13.69
length 8
width 8.1
country of origin MX
weight 1.327500