Specifications

Item Variable Frequency Drive
Accepts Input Control Signal Remote Contact
Adjustable Acceleration Time 0.01 sec. to 6000 sec.
Adjustable Deceleration Time 0 sec. to 6000 sec.
Application Fans, Pumps, Wire Drawing
Brake Chopper Included Yes
Color Blue
Control Method V/F Control (Im), Dynamic Torque Vector Control (Im), V/F Control With Slip Compensation (Im), V/F Control With Encoder Option (Im), Vector Control With Encoder Option (Im), Sensor Less Vector Control (Pmsm)
Control Type Remote Keypad, Communication Option Adapter
Depth 6.22"
Digital Readout Output Current, Output Voltage, Calculated Torque [%], Input Power [Kw], Timer (Timer Operation)[S], Load Factor [%], Motor Output [Kw]
Display Type LED
Displays System Operation And Associated Value Conversion, Status Of I/O, Operations And Alarms
Dynamic Braking Yes
Enclosure Open
Enclosure Rating NEMA 1
Ethernet Port Included No
Height 9.05"
Input Frequency 50/60 Hz
Input Phase 3
Input Phase Ac 3
Input Type Analog, Digital
Input Voltage 460V AC
Input Voltage Range 380-480V AC +10%/-15%
Key Pad Lockout Password Lockout
Max. Hp 10 hp
Max. Output Amps 17.5A
Maximum Output Power 10 hp
Number Of Inputs (5) Digital, (2) Analog
Number Of Outputs (3) Digital, (2) Analog
Output Frequency 0-400 Hz
Output Frequency Range 500 Hz
Output Phase Ac 3
Output Type Analog, Digital
Output Voltage 460V AC
Output Voltage Range 0-460V AC
Overall Depth 6 1/4"
Overall Height 9"
Overall Width 7 1/8"
Protection Auto Reset, Auto Restart After Momentary Power Failure, Droop Control, Overload Stopping
Series FRENIC-ACE Series
Start/stop Control Programmable
Starting Torque 150%
Style Heat Sink
Torque @ 1 Hz 150%
Torque Application Constant Torque, Variable Torque
Width 7.09"
With Bypass/no Bypass No Bypass
With Line Contactor/no Line Contactor No Line Contactor
standard UL/CUL 508C C22.2 NO.14, CE, ROHS, GOST-R, KC

Product Details

Fuji Electric FRN0022E2S-4GB variable frequency drive (VFD) is ideal for regulating the speed and torque of an electric motor. It is used in industrial automation, providing precise motor control and energy savings in various applications such as pumps, fans and conveyors.

Shipping Information

height 22.99
length 15.8
width 18.01
country of origin TW
weight 1.994600

Uses

Working Mechanism

  • The VFD receives AC power which is then converted to DC power by a rectifier, preparing it for further processing.
  • The DC passes through a DC bus that contains capacitors; these capacitors stabilise the DC voltage, ensuring its consistency.
  • An inverter subsequently converts the stabilised DC back into AC, utilising techniques such as pulse width modulation.
  • The AC output, now modified, regulates the motor speed by altering the frequency of the electricity supplied to the motor.
  • Sensors continually monitor the motor's performance and send feedback to VFD, enabling real-time adjustments to secure optimal operation across various load conditions.

Features

  • It features a NEMA 1 enclosure for protection against dust and indirect moisture.
  • This variable frequency drive has programmable start / stop control to optimise the start-up and shut-down of connected motors.
  • It comes with dynamic braking to rapidly decelerate the motor using the drive's energy for requiring quick stops.
  • This variable frequency drive offers an LED for clear, bright readouts of operational data and settings for easy monitoring even in low-light conditions.

Compatible Accessories

Standards and Approvals

Installation

FAQ′s

Q. How do adjustable acceleration and deceleration times contribute to customising the Variable Frequency Drive?

A. Adjustable acceleration and deceleration times allow users to customise the speed at which the motor ramps up or down. This customisation is essential for adapting the drive to specific operational needs and preventing sudden jolts or stops.

Q. How does the VFD process input control signals and contribute to integrating external control?

A. The VFD accepts input control signals through remote contacts, providing flexibility for external control integration and seamless integration with other systems or external controllers for coordinated operation.

Q. How to control this three phase 5.5 / 7.5kW electric inverter?

A. It features a remote keypad allowing for flexible, user-friendly operation away from the drive's physical location.

Q. Is Fuji Electric FRN0022E2S-4GB variable frequency drive protected from unauthorised usage?

A. It features password lockout to prevent unauthorised access to configuration settings, ensuring operational security.

Q. What factors should be considered while selecting a VFD?

A. Major factors include motor horsepower, voltage & current ratings, enclosure type, communication protocols and application requirements.