| Circuit Breaker Type | Number Of Poles | Voltage | Price |
|---|---|---|---|
| EG | 3 | 347/600V AC | £1632.29 |
| EG | 3 | 347/600V AC | £1600.18 |
| EG | 3 | 347/600V AC | £1600.18 |
| EG | 3 | 347/600V AC | £1632.29 |
| EG | 3 | 347/600V AC | £1600.18 |
| EG | 3 | 347/600V AC | £1632.29 |
| EG | 3 | 347/600V AC | £1959.11 |
| EG | 3 | 347/600V AC | £1928.9 |
| EG | 3 | 347/600V AC | £1600.18 |
| EG | 3 | 347/600V AC | £1600.18 |
| EG | 3 | 347/600V AC | £1600.18 |
| EG | 3 | 347/600V AC | £1632.29 |
| EG | 3 | 347/600V AC | £1632.29 |
| EG | 3 | 347/600V AC | £1632.29 |
| EG | 3 | 347/600V AC | £1959.11 |
| EG | 3 | 347/600V AC | £1600.18 |
| EG | 3 | 347/600V AC | £1928.9 |
| EG | 3 | 347/600V AC | £1928.9 |
| EG | 3 | 347/600V AC | £1959.11 |
| EG | 3 | 347/600V AC | £1959.11 |
| EG | 3 | 347/600V AC | £1928.9 |
| EG | 3 | 347/600V AC | £1632.29 |
Working Mechanism
- These circuit breakers are equipped with fixed thermal and fixed magnetic trip mechanisms to protect electrical systems against overload conditions:
Fixed Thermal Trips
- The thermal trip uses a bimetallic strip that is sensitive to changes in temperatures. When the current flow exceeds the rated value, the strip heats up and bends.
- This causes the contacts to open and interrupt the current flow.
Fixed Magnetic Trips
- The magnetic trip consists of an electromagnetic component that detects the presence of short circuits in a circuit. As the current rises, a magnetic field is generated that causes the displacement of the plunger in the tripping coil, forcing the contacts to open and interrupt the flow.
Features
- These circuit breakers feature a fixed thermal & fixed magnetic trip that offers reliable overload and short-circuit protection, thus protecting wire and the equipment from damage.
- They also include a front-mounted handle that can be used to manually trip or reset the breaker.
- These circuit breakers have moulded cases to hold current-carrying components, trip devices and mechanisms integrated into one unit.
- Their three-pole design provides interrupting ratings of 35kA at 240VAC, 25kA at 480VAC and 18kA at 600Y / 347VAC, respectively.
Frequently Asked Questions
Q. How is the tripping status indicated?
A. Eaton moulded case circuit breakers feature a trip flag to provide a visual indication of the TRIPPED and OFF status of the breaker.
Q. How to reset a moulded case circuit breaker that has been tripped?
A. A tripped breaker can be reset again by pressing the OFF and then the ON pushbutton, which closes the breaker contacts and retracts the current flow.
Explore More
- KEYSHAFT
- LEGACY
- GORILLA MILL
- RIP TIE
- R W ROGERS COMPANY
- Basket Truck Accessories
- CPVC Pipe Fittings
- Crossover Ladder Accessories
- Grease Feeders
- Damage Indicator Labels
- RUD CHAIN RS Eye Bolts, Pipe Thread
- TYGON 2375 Chemical Resistant PVC Tubings
- GLOBE SCIENTIFIC Screwcaps without O-Ring, for Sample Tubes
- ANVIL AS1300 Series Universal Clamps, Electro Galvanized
- ANVIL AS809 Series Double Channel Brackets
- EAGLE Decorative Cigarette Receptacle
- EATON CH Series Standard Circuit Breakers
- HUBBELL Straight-Blade Receptacles
- WILKERSON FRLs R03 Series Miniature Regulators