| Circuit Breaker Type | Number Of Poles | Type | Voltage | Price |
|---|---|---|---|---|
| E2M | 3 | Specialty Complete | 250V DC | RFQ |
| E2M | 3 | Specialty Complete | 250V DC | £17400.51 |
| E2M | 3 | Specialty Complete | 250V DC | £17400.51 |
| E2M | 3 | Specialty Complete | 250V DC | £15523.71 |
| E2M | 3 | Specialty Complete | 250V DC | RFQ |
| E2M | 3 | Specialty Complete | 250V DC | £17400.51 |
| E2M | 3 | Specialty Complete | 250V DC | £17400.51 |
| E2M | 3 | Specialty Complete | 250V DC | RFQ |
| E2M | 3 | Specialty Complete | 250V DC | £15523.71 |
| E2M | 3 | Specialty Complete | 250V DC | £15523.71 |
| E2M | 3 | Specialty Complete | - | £15523.71 |
| E2M | 3 | Specialty Complete | 250V DC | £17400.51 |
| E2M | 3 | Specialty Complete | 250V DC | £15523.71 |
Features
- These MCCBs feature a front-adjustable magnetic trip providing instantaneous tripping in current surge exceeding the trip settings, thus signalling the actuator to open the contacts and interrupt current.
- They have moulded cases to hold current-carrying components, trip devices and mechanisms integrated into one unit.
- These circuit breakers have a three-pole design with interrupting ratings of 35kA at 480VAC, 25kA at 600VAC and 65kA at 240VAC.
- They come with an enhanced, easy-to-use interface, allowing the user to view and make adjustments to the trip unit settings.
Frequently Asked Questions
Q. What is the difference between non-interchangeable and interchangeable circuit breakers?
A.
- When the trip unit in non-interchangeable or fixed breakers needs to be replaced, the entire breaker needs to be changed.
- In interchangeable breakers, only the trip needs to be replaced without opening the whole unit.
Q. How is the tripping status indicated?
A. Eaton moulded case circuit breakers feature a trip flag to indicate the TRIPPED and OFF status of the breaker.
Q. What is the breaking capacity of an MCCB?
A. The breaking capacity of an MCCB is defined as the maximum level of fault current which can be safely cleared by tripping, thus preventing permanent damage.
Q. How to reset a moulded case circuit breaker that has been tripped?
A. When the breaker trips, it can be reset again by pressing the OFF and then the ON pushbutton, which closes the breaker contacts and starts the current flow.
Explore More
- APW WYOTT
- KEYSHAFT
- WILLIAMS INDUSTRIAL TOOLS
- RUTHERFORD
- ADVANCED CABLE TIES
- Door Knob Locksets
- Caulks
- Hose Safety Cables
- Shaft And Step Plate Adapters
- Hardware Cloth
- DESTACO 210 Series Vertical Hold Down Clamps
- DESTACO 89R Series Pneumatic Swing Clamp Arms
- MEMPHIS GLOVE Big Jake Premium Palm Work Gloves
- GLOBE SCIENTIFIC Diamond RealSeal Bottles, Narrow Mouth, LDPE
- QORPAK Flint Glass Type III - Plasticote Safety Coated Bottle
- METRO Solid Shelf
- SPEEDAIRE Hose Barb 90 Degree Brass
- BISHOP-WISECARVER UtiliTrak Series Linear Guide Tracks
- DAYTON Permanent Split Capacitor AC Gearmotors, Open, 115V AC, 60/50 Hz