| Number Of Poles | Circuit Breaker Type | Voltage | Type | Price |
|---|---|---|---|---|
| - | - | - | - | £11317.39 |
| 3 | E2KE | 600V AC/250V DC | Specialty Complete | £11002.26 |
| 3 | E2KE | 600V AC/250V DC | Specialty Complete | £11317.39 |
| 3 | E2KE | 600V AC/250V DC | Specialty Complete | £11704.5 |
| 3 | E2KE | 600V AC/250V DC | Specialty Complete | £10638.37 |
| 3 | E2KE | 600V AC/250V DC | Specialty Complete | £11704.5 |
| 3 | - | 600V AC/250V DC | Specialty Complete | £10638.37 |
| 3 | E2KE | 600V AC/250V DC | - | £11182.63 |
| 3 | E2KE | 600V AC/250V DC | Specialty Complete | £11002.26 |
| 3 | E2KE | 600V AC/250V DC | Specialty Complete | £11002.26 |
| 3 | E2KE | 600V AC/250V DC | Specialty Complete | £9016.36 |
| 3 | E2KE | 600V AC/250V DC | Specialty Complete | £11704.5 |
| 3 | E2KE | 600V AC/250V DC | Specialty Complete | £9016.36 |
| 3 | E2KE | 600V AC/250V DC | Specialty Complete | £12416.53 |
| 3 | E2KE | 600V AC/250V DC | Specialty Complete | £11002.26 |
| 3 | E2KE | 600V AC/250V DC | - | £9948.84 |
| 3 | E2KE | 600V AC/250V DC | Specialty Complete | £10514.54 |
| 3 | E2KE | 600V AC/250V DC | Specialty Complete | £11704.5 |
| 3 | E2KE | 600V AC/250V DC | Specialty Complete | £11002.26 |
| 3 | E2KE | 600V AC/250V DC | - | £11002.26 |
| 3 | E2KE | 600V AC/250V DC | Specialty Complete | £12445.8 |
| 3 | E2KE | 600V AC/250V DC | Specialty Complete | £10495.05 |
| 3 | E2KE | 600V AC/250V DC | Specialty Complete | £12445.8 |
| 3 | E2KE | 600V AC/250V DC | - | £11002.26 |
| 3 | E2KE | 600V AC/250V DC | Specialty Complete | £13508.97 |
Features
- They feature interchangeable magnetic only / thermal-magnetic trip for long & instantaneous short circuit protection.
- These circuit breakers have an amperage rating of 400A and are available for systems up to 600VAC / 250VDC.
- They come with K frames to minimise unit damage.
- They feature a high-speed blow-open action for enhanced performance.
- These mining breakers are equipped with an electronic trip unit and a built-in test port for easy field testing with a 120VAC test kit.
Frequently Asked Questions
Q. What are the interrupt ratings of these circuit breakers?
A.
- 65kAIC at 240VAC
- 35kAIC at 480VAC
- 25kAIC at 600VAC
- 10kAIC at 250VDC
Q. Which type of frames are used in these Eaton E2KE type circuit breakers?
A. Complete breaker frames are used to protect the internal parts of the breaker from the outer parts.
Explore More
- BULLDOG
- KEYSHAFT
- QORPAK
- FAG BEARINGS
- VERIS
- Divider Box Accessories
- Timer Accessories
- Task Lighting
- Floor, Table And Jobsite Fans
- Intrusion Systems
- ANSELL 02-100 Alphatec Highly Chemical Resistant Gloves
- CHICAGO PNEUMATIC QRS Series Rotary Screw Air Compressors With Air Dryer
- LAMP ESR-4513 Series Full Extension Drawer Slides
- MUELLER INDUSTRIES 105MAT Silent Check Valves
- DYNALON Scoop Hdpe
- BANJO FITTINGS Valve Repair Kit, Stainless Steel
- WARING COMMERCIAL MX Series Blender
- ANVIL Grooved Tees