| Number Of Poles | Ac Voltage Rating | Phase | Voltage | Min. Wire Size | Dc Voltage Rating | Circuit Breaker Actuator | Circuit Breaker Mounting Style | Price |
|---|---|---|---|---|---|---|---|---|
| 1 | - | - | 120/240V | - | - | - | - | £146.13 |
| 1 | - | - | 120/240V | - | - | - | - | £571 |
| 1 | - | - | 120/240V | - | - | - | - | £571 |
| 1 | - | - | 120/240V | - | - | - | - | £118.29 |
| 1 | - | - | 120/240V | - | - | - | - | £118.29 |
| 1 | - | - | 120/240V | - | - | - | - | £146.13 |
| 1 | 120/240V AC | Single | - | 14 AWG | Not Rated | Toggle | Plug In | £75.3 |
| 2 | - | - | 120/240V | - | - | - | - | RFQ |
| 2 | - | - | 120/240V | - | - | - | - | RFQ |
| 2 | - | - | 120/240V | - | - | - | - | £551.79 |
| 2 | - | - | 120/240V | - | - | - | - | RFQ |
Working Mechanism
- Eaton AFCI circuit breakers utilise sensors to monitor the electrical current flowing through the circuit.
- When the circuit breaker detects an arc fault, it interrupts the flow of electricity to prevent fire risks.
Features
- Eaton CH AFCI circuit breakers have an LED to indicate one of the seven trip codes to simplify circuit diagnostics.
- These circuit breakers provide branch overvoltage protection for sensitive electronics and have an interrupt rating of 10kIAC.
- Their thermal-magnetic trip curve avoids nuisance tripping on mild overloads but reacts almost instantaneously to severe short-circuit conditions.
- Selected models have trip flags to differentiate between a 'trip' and the 'breaker being turned off' conditions.
Frequently Asked Questions
Q. What is the difference between an AFCI and GFCI?
A. GFCI protects people from electric shocks due to a ground fault, whereas the AFCI protects the branch circuit wiring from dangerous arcing faults.
Q. What is an arc fault?
A. Arc fault is an unintended arc created by current flowing through an unplanned path. Arcing creates high-intensity heating that results in burning particles that may easily ignite surrounding material, such as wood framing or insulation.
Q. Can AFCI circuit breakers be reset?
A. Yes, AFCI circuit breakers can be reset after they trip or shut off due to an arc fault.
Q. Can AFCI circuit breakers be used with surge protectors?
A. Yes, AFCI circuit breakers can be used with surge protectors.
Explore More
- HUOT
- KEYSHAFT
- NIROFLEX USA
- TRUE HARDWARE
- CCEALIGHTS
- Check and Foot Valves
- Ball Pein Hammers
- Lighting Control System Components
- Trailer Hitches and Step Bumper Hitches
- Concrete Grabs and Slab Tongs
- LOUISVILLE AS4000 Series Aluminium Step Ladders
- OIL SAFE Drum Workstation QC Upgrade Kits
- PROTO Extra Thin Open End Wrench, SAE
- VERMONT GAGE Npsm Straight Pipe Plugs, Go/NoGo Member
- SPEARS VALVES CPVC New Style Standard Tank Adapters With Neoprene Gaskets, Socket x Fipt
- FABORY M12 x 1.25 Fine Black Oxide Hex Head Cap Screws
- BALDOR / DODGE Housings