MARATHON MOTORS Condenser Fan/Heat Pump Motors, PSC, Open Air Over, Thru-Bolt, Shaft Up or Horizonal

Marathon condenser fan / heat pump motors are suitable for driving HVAC equipment for ventilation applications. Marathon also offers heavy duty fan motors that are suitable for driving heavy duty fans & blowers.

Filter
Assembly: F1 ONLY , Hz: 60 , Insulation Class: B , Mounting: Extended Studs - Footless , NEMA Design: NO DESIGN CODE , Phase: 1
StyleModelRotationDutyEnclosureRPMService FactorThermal ProtectionVoltageFramePrice
A
5KCP49ZN9617T
Select Counter clockwiseContinuousOpen10751.0Automatic200-230/46056Z£948.99
B
048A11O1771
SELECTIVE CCWCONT.AOMOPAO10751.0Automatic Protector (under locked rotor only)57548Y£165.82
C
048A11O2054
SELECTIVE CCWCONT.AOMOPAO1075-Automatic Protector (under locked rotor only)46048Y£320.03
D
048A17O172
SELECTIVE CCWCONT.AOMOPAO1625-Automatic Protector (under locked rotor only)46048Y£561.84
B
048A11O840
SELECTIVE CCWCONT.AOMOPAO1075NONEAutomatic Protector (under locked rotor only)208-23048Y£607.88
E
048A11O2016
SELECTIVE CCWCONT.AOMOPAO1075-Automatic Protector (under locked rotor only)46048Y£444.83
F
048A11O1524
SELECTIVE CCWCONTINUOUS AOMOPAO10751.0Automatic Protector (under locked rotor only)208-23048Z£448.45
G
048A11O678
SELECTIVE CCWCONT.AOMOPAO10751.0Automatic Protector (under locked rotor only)208-23048Y£690.17
H
048A11O2017
SELECTIVE CCWCONTINUOUS AOMOPAO1075NONEAutomatic Protector (under locked rotor only)46048Z£381.62
I
048A17O169
SELECTIVE CCWCONT.AOMOPAO1625NONEAutomatic Protector (under locked rotor only)46048Y£392.42

Features

  • Marathon condenser fan / heat pump motors feature automatic thermal protection for preventing damage against overheating.
  • They have vertical / horizontal mounting capability for easy installation depending upon the application requirement.
  • They feature a thru-bolt mount design that prevents the motor from getting out of position during operation.
  • These motors have an open air over enclosure for high airflow inside the motor enclosure.

Standards and Approvals

  • UL

Frequently Asked Questions

How does a PSC motor start?

  • After a capacitor start or split phase motor starts, the centrifugal switch on the shaft opens and disconnects the start winding or capacitor.
  • The motor then runs using the run winding only.

Are Marathon condenser fan / heat pump motors prone to overheating?

These motors have automatic thermal protection, preventing the motor from overheating in low ventilation environments.

Do Marathon condenser fan / heat pump motors require frequent lubrication?

These motors have pre-greased ball bearings that are inside the motor enclosure and do not require frequent lubrication.

How to install Marathon condenser fan / heat pump motors?

These motors have a long shaft directly mounted onto the load / fan. The motor is connected to the fan assembly using thru bolt mounting.