Installation accessories, such as ceiling mount brackets, rocker switches, floor pedestals, misting hub kits and wall brackets, designed for use with air circulators
Close-mesh steel wire guards available for propeller diameters ranging from 16 to 36 inches. Feature a rear-section design with 4 mounting slots to accommodate motor thru-bolts
Stationary and mobile air circulators capable of delivering air flows up to 21000 cfm. Feature steel / aluminium blades with a powder-coated finish to resist corrosion and offered in wall and pedestal mounting options
Dayton axial fans are commonly used for cooling in compact spaces including cabinets, electronic instruments, copy machines and computers. For wear reduction & damage protection, these fans monitor temperature by discharging hot air and allowing cool air inside the enclosure. Dayton axial fans are generally placed near heat generating power sources & motors, allow both horizontal & vertical mounting and are equipped with ball bearings for reducing rotational friction & protecting the enclosure from dust particles. Raptor Supplies is an authorised Dayton distributor hosting a huge selection of these axial fans with auto & impedance thermal protection and speeds ranging from 1400 to 3200 rpm.
Raptor Supplies offers a wide range of Dayton infrared gas tube heaters designed for large industrial and commercial heating applications such as high ceilings, spot heating, warehouses and service garages. These low-intensity tube heaters feature a highly polished reflector that adjusts from 0 to 45 degrees to provide optimal heat coverage by directing the energy to floor level. Capable of providing effective heating under most diverse and challenging conditions, these heaters can offer outputs more than 100000 BtuH. Offering lower clearance to combustibles, they have stainless steel burners and include mounting chains, flexible gas connectors and gas shutoff. Equipped to accept outside combustion air, these units are provided in two gas type models - liquified propane (LP) & natural gas (NG) - on Raptor Supplies, an authorised Dayton distributor.
Dayton HVAC dampers (also called duct dampers) are located inside air-handling equipment such as duct systems, chimneys & VAV boxes to regulate airflow and redirect it to specific areas. These dampers feature high quality galvanised steel bodies & extruded aluminium blade material for preventing rust formation and enduring outside weather, respectively. Mostly used with ductwork of low to medium airflow velocity, these control dampers can be utilised as positive shutoffs to keep the machine from over-speeding and getting damaged or for automatic control in low-leakage HVAC systems. The backdraft dampers used in ventilation systems are low-leakage control dampers with spring-assisted blades that restrict airflow to one direction only so that the ventilation system works correctly. Dayton volume control dampers are offered in round and square designs to serve different applications of controlling airflow and pressure in HVAC systems.
Dayton fire and smoke dampers are employed in office buildings, healthcare facilities and HVAC duct systems to prevent the spread of fire and smoke in case of a fire. Dayton fire dampers adhere to UL, NFPA and IBC regulations and can accommodate airflow in any direction. Dampers must be kept clean and safe from dirt, dust and other foreign elements before and after installation. When installed inside HVAC ductwork, the damper blades automatically close when a rise in temperature is detected or a smoke alarm goes off. Dynamic mount fire dampers feature steel spring-assist closing of the blades and velocity & pressure ratings of 2000 fpm & 4 inch wg, respectively. Static mount type dampers are ideal for zero pressure systems. Dayton fire and smoke dampers are capable of withstanding temperatures up to 165 degrees F and offer fire resistance for 1.5 hrs. Choose from a broad range of round (with single blade), rectangular & square (with curtain blade) type dampers in sizes that fits your ductwork, fusible links & retaining angle frames on Raptor Supplies, the brand's authorised distributor.
Includes HEPA carbon filters and prefilters, Ti02 filters, bag filters and carbon filters designed for use with air cleaners to remove large particles, particulates and odours
Replacement UV bulbs for use with Dayton air cleaners to neutralise the effect of bacteria, virus or other microorganisms
Dayton's product line includes heavy duty V-belts, gear belts, farm duty motors, washdown motors, AC / DC gearmotors, speed reducers & gear drives, transformers, ventilators, steel cables, web slings, shaft collars, relays, air circulars, shutters, blowers and drum pumps. Dayton gearmotors are used to adjust torque & speed and are ideal for use in peristaltic pumps, CNC machines and automotive applications. Dayton V-belt, one of the company's best-selling products, conforms to Rubber Manufacturers' Association (RMA) standards and is extensively used as a transmission belt. Dayton air curtain blowers are designed to produce a wall of continuously flowing air that provides a thermal barrier against outside air and prevents heated or cooled air from escaping through open doorways. High traffic areas can leave their doors open, keeping flying insects out & eliminating the hassle caused by automatic / manual doors opening and closing. They reduce humidity and loss of cold air. The brand also offers OEM blowers ideal for replacing worn-out motors on HVAC devices. The Dayton 1TDP6 blower feature cast aluminium end shields for heat dissipation and a dynamically balanced design for smooth and quiet operation. The motor on these blowers facilitate auto thermal protection to prevent overloads or phase failure.
All Dayton motors are provided with full fact nameplates having easy to read wiring diagrams. This reduces installation time and prevents miswiring.
General purpose motors are used for mechanical loads (eg: air movement) and hard to start applications such as conveyors, belt driven equipment, machine tools & reciprocating pumps. These motors have a rugged design and heavy duty ball bearings for handling large radial & axial loads. Specific purpose motors are intended for washdown / hazardous locations / pump duty. HVAC motors are designed for air movement and other light to medium duty applications, such as fans, centrifugal pumps, small tools & office equipment.
Yes, Dayton provides cleaning & janitorial supplies to keep commercial and industrial facilities clean and well maintained. They clean, degrease, sanitise and disinfect walls, floors & other surfaces. Cleaning supplies from Dayton include mops, brooms & floor cleaning machines that clean, scrub, strip, buff, polish or vacuum floors and carpets.
It may be possible to use a run capacitor as a start capacitor, however, the available values are much lower than those for dedicated start capacitors. To ensure that the run capacitor matches the original start capacitor specification, it must have the same capacitance rating and voltage rating.
Selecting the appropriate Dayton blower depends on the required airflow, static pressure, application environment and industry standards or regulations.
The top end of Dayton water tanks has an inlet / outlet for connecting the piping system to the water pump on the other end. The water tanks can be stored horizontally or vertically.